On this page
Quick answer
Common causes include a tripped breaker, incorrect thermostat setting, open thermal cutoff, failed heating element, plumbing restriction, or an extinguished gas pilot. First identify electric or gas, restore the correct power or gas service, check temperature settings, and follow safe status checks. Stop before wiring, gas components, plumbing, or tank access and call a professional if needed.
At a glance
- Time
- 20–60 min
- Difficulty
- Moderate
- You'll need
- Flashlight, owner’s manual, and a stable step stool
- Cost
- Free for checks; parts or service if a component failed
- Works on
- Residential electric and gas tank and tankless water heaters
- Not covered
- Internal wiring, gas components, sealed-tank repairs, and replacement installation
Why is my water heater not heating?
A conventional storage water heater keeps hot water in an insulated tank. A thermostat measures the water temperature and turns on the heat source when needed. Electric heaters use one or more heating elements, while gas heaters use a burner controlled by a pilot or electronic ignition system.
No hot water can mean that power or gas service is interrupted, a safety control has opened, the thermostat is not calling for heat, or a heating component has failed. A water heater that produces hot water briefly may instead be working but unable to keep up with demand. Low flow, a clogged faucet, or a thermostatic mixing valve can also make one fixture behave differently from the rest of the house.
Tankless heaters have no storage tank. They heat water as it flows through a heat exchanger, so adequate flow, clean internal passages, correct fuel, and a normal control cycle are all necessary. The safest approach is to identify the heater type, make external checks, and stop before opening panels or disturbing gas, water, or electrical connections.
Before you start
Identify the unit as electric or gas before changing anything. Read its owner’s manual and note the control type, status lights, and warning messages. Open a hot-water outlet only when you can handle very hot water, and use a stable step stool rather than a chair or countertop.
Gas emergency: If you smell gas or a carbon-monoxide alarm sounds, leave the building immediately. Do not operate a switch, use a phone inside, light a flame, approach the pilot, or try to relight the unit. Call the gas utility or emergency services from outside.
For an electric heater, switch off its labeled breaker before opening any control area. For a plug-in unit, unplug it. Before loosening any connection to a water heater, close its cold-water supply valve. Do not open the tank, remove a heating element, or touch internal wiring. A licensed professional must handle gas valves, lines, burners, and component-level gas work.
- Have ready: A flashlight, the owner’s manual, a stable step stool, and a way to identify the unit’s breaker and fuel type.
- Record first: Any status code, clicking sound, pilot condition, error message, leak, odor, or repeated breaker trip.
- Stay away from: Scorched wiring, wet electrical parts, bulging tank walls, leaking gas, and a damaged flue or vent.
- Avoid: Bypassing a safety switch, lighting a match to test for gas, or repeatedly resetting a unit that trips again.
Step 1 Restore power or confirm gas service
Why this fix works. An electric heater cannot heat without power, and a gas heater with electronic ignition also needs electricity. A utility gas interruption can prevent a gas heater from operating.
For an electric heater
- Read the label without opening a panel. Check the correctly labeled breaker. If it has tripped, switch it fully off and then back on.
- If the breaker trips again, leave it off. Repeated trips can indicate a damaged circuit, cord, heating element, or internal connection that needs professional attention.
- For a plug-in unit, inspect the plug only from a safe distance. If it is hot, cracked, wet, or discolored, do not touch it; unplug it if safe and arrange service.
For a gas heater
- From a safe location, check whether the gas utility has reported a service interruption.
- If gas service is off at the meter, have the utility restore it. Never test for gas with a flame, and do not operate the heater’s gas valve yourself.
- If you smell gas, leave the area instead of approaching the appliance.
How to tell whether it worked. The breaker should remain on, the controls should show a normal state, and hot water should return after the recovery period described in the manual. A breaker that trips again or gas service that remains unavailable requires professional help.
Step 2 Set the thermostat and control mode
Why this fix works. A heater may have power and fuel but still not heat when it is switched off, left in vacation mode, or set below the required temperature. A correct setting also restores the heating cycle after some brief interruptions.
For a storage heater
- Locate the external thermostat or control panel without removing any cover. Check for an off or vacation setting and return the unit to normal heating operation.
- For a mechanical control, move the dial only within the marked temperature range. For a digital control, use the temperature and mode controls as described in the manual.
- Confirm that the control shows or requests heat. If it remains on any warning or fault indicator, record the message and follow the manual’s troubleshooting procedure.
For a tankless heater
- Open one hot-water tap at a moderate flow so the unit can detect flow. Avoid running several fixtures at once while checking the startup sequence.
- If the display shows a fault, do not keep resetting it. Record the exact message and identify whether the problem involves flow, temperature, power, gas, or venting.
Use a moderate water temperature and follow the manufacturer’s recommended range. Raising the setting too high can create a scalding hazard without fixing a failed heating component.
How to tell whether it worked. The control should enter an active heating cycle, and hot water should become available after the unit’s normal recovery time. If the settings have no effect, continue with the symptom-specific checks below.
Step 3 Restore and verify a gas pilot
Why this fix works. Many gas storage heaters use a standing pilot to supervise ignition. If that pilot is out, the burner will not start even when the thermostat calls for heat. Other designs use electronic ignition, so a small flame that blinks or disappears may be normal.
Before this step: If there is any gas odor, do not approach the unit. For a non-emergency inspection, switch off the water-heater breaker. Do not remove a cover, adjust a gas valve, or work on the burner.
If you smell gas
- Leave the building without operating switches or creating sparks.
- Do not try to relight the pilot or call from an unsafe location.
- From outside, contact the gas utility or emergency services and wait for instructions.
If there is no gas odor
- Look through the manufacturer’s viewing window and determine whether a steady pilot is present. Some electronic-ignition systems show a brief flame instead.
- If the manual provides a user-approved lighting procedure, follow it exactly. Do not remove the front cover or bypass a flame sensor, thermocouple, or safety control.
- If the pilot lights but goes out again, stop repeated attempts. A unit that will not remain lit needs inspection by a licensed gas professional.
- If no user lighting procedure is provided, or the unit does not relight, arrange professional service.
How to tell whether it worked. A standing pilot should remain lit, the control should stay in normal operation, and hot water should return after the recovery period. An unstable flame, repeated shutdown, unusual smell, or soot near the unit means service is needed.
Step 4 Reduce hot-water demand and test recovery
Why this fix works. A storage heater can run out of hot water when several fixtures operate at once. A tankless heater may stop heating when flow falls below its operating range. Testing with one moderate-flow outlet can separate a demand problem from a complete heating failure.
- Stop the dishwasher, laundry equipment, hot tub, and other hot-water loads while you test.
- Open one hot tap at a moderate flow. Notice whether the water starts cold, becomes warm, or remains cold from the beginning.
- For a storage heater, close the tap, allow the recovery time listed in the manual, and test again. Hot water that returns only after the wait may indicate a capacity or recovery problem.
- For a tankless heater, increase and decrease the flow slowly. Water that weakens as flow rises may indicate scale, a restricted inlet, or a water-pressure problem.
- If the heater works only when demand is low, have a professional assess its capacity and heating condition rather than repeatedly raising the temperature.
How to tell whether it worked. One outlet should provide usable hot water during moderate use after recovery. If the tank empties quickly or the tankless unit shows a flow fault, the underlying supply or heating condition still needs attention.
Step 5 Reset an accessible electric thermal cutoff
Why this fix works. A high-limit thermal cutoff can open when the tank becomes too hot. On some models, an accessible reset control returns the heater to operation after the cause of overheating has been corrected.
Before this step: Switch off the water-heater breaker or unplug the unit. Do not remove a control cover or electrical panel. If water is leaking near the heater, leave the breaker off and call a professional.
- Consult the owner’s manual to determine whether the model has a user-resettable high-limit control.
- Find only the reset control the manual identifies. Do not bridge, jumper, or bypass a thermal cutoff, thermostat, or other safety device.
- Restore the reset control according to the manual, then switch the breaker back on or reconnect the plug.
- Allow the heater to complete a heating cycle before testing a hot-water outlet.
- If there is no reset control, resetting has no effect, or the breaker trips again, leave the unit off and call a water-heater technician.
How to tell whether it worked. The unit should return to normal heating, remain powered, and produce hot water after recovery. Repeated cutoff trips indicate that the underlying cause has not been repaired.
Step 6 Identify a failed electric heating component
Why this fix works. If power, settings, and safety controls are normal, the thermostat itself or a heating element may have failed. One failed element can leave a storage heater able to produce only a short supply of hot water. Sediment and mineral buildup can also interfere with heat transfer.
- Confirm that the heater is electric and that the breaker stays on after the checks in Step 1.
- Test the nearest and farthest hot-water outlets. Note whether the water is completely cold, briefly hot, or gradually cools.
- Compare the pattern with the thermostat display. A control that visibly requests heat but produces no hot water points toward the heating circuit rather than a supply interruption.
- Do not remove the lower access panel, touch a heating element, or test internal wiring yourself. Those checks require a technician to disconnect power and verify the thermostat, elements, cutoff, and connections safely.
- Ask a qualified water-heater technician to inspect the failed component and check for sediment, scale, corrosion, or a tank that cannot be repaired.
How to tell whether it worked. After repair or replacement, the heater should maintain its selected temperature without tripping the breaker or repeatedly resetting a safety control. Hot water that returns only briefly means at least one heating path is still not working.
Step 7 Check the faucet and mixing valve
Why this fix works. If the heater is producing hot water but one outlet remains cold, the problem may be downstream. A clogged aerator, a closed fixture valve, a blocked supply line, or a thermostatic mixing valve can change the temperature at one location.
Before this step: Close the hot-water supply valve beneath the affected sink before removing any faucet part. Let the faucet cool, and do not disconnect any pipe connected to the heater.
- Check every hot-water valve under the affected sink and confirm that the hot outlet is open.
- Remove the aerator by hand, rinse it, and check for mineral or debris buildup. Reinstall it securely without forcing it.
- Run the tap and observe whether the water warms normally. If it remains cold at that fixture but is hot elsewhere, contact a plumber to inspect the valve and supply line.
- If one outlet is dangerously hot while another is cold, look for a thermostatic mixing valve. Follow its manual for permitted adjustment or have a plumber service it.
- Do not tamper with the temperature-pressure relief valve, pressure-reducing valve, or heater plumbing unless the manufacturer’s instructions specifically cover the task.
How to tell whether it worked. The affected outlet should produce water at a safe, steady temperature similar to the other fixtures. If it remains cold, unusually hot, or changes temperature without demand, the fixture or mixing device needs professional repair.
Step 8 Check tankless flow, venting, and fault codes
Why this fix works. Tankless heaters need continuous flow and clean heat-transfer passages. A restricted inlet, scale buildup, blocked vent, or active fault can stop heating even when electricity and gas are available.
- Open one hot tap at a moderate flow and watch the unit’s display. Confirm that it detects flow and enters its heating sequence without showing an immediate fault.
- Read and record any error code before changing settings. Follow the manual’s listed shutdown and restart procedure once, but do not repeatedly reset an unexplained fault.
- Inspect the visible portion of the vent termination from the ground for obvious blockage, damage, or debris. Do not climb onto the roof or remove a vent cap.
- Look around the inlet connection for visible moisture without loosening it. If there is a leak, close the heater’s water supply if it can be done safely and call a plumber.
- If the manual recommends descaling and you are not experienced with the procedure, have a qualified technician service the unit. Scaling work on a gas or hardwired model can involve electrical, gas, and water connections.
- If the fault returns or hot water stops after brief operation, arrange service for the flow sensor, heat exchanger, controls, or venting system.
How to tell whether it worked. A tankless unit should detect flow, complete its heating cycle without a recurring fault, and deliver hot water at the selected temperature. A blinking error light or shutdown after use means the underlying fault remains.
Symptom checker
| What you notice | Likely cause | Fix (step number) |
|---|---|---|
| No hot water anywhere; breaker is off | Tripped breaker or interrupted power | Step 1 |
| No hot water; display is off or in vacation mode | Incorrect control mode | Step 2 |
| Gas storage heater has no standing pilot | Pilot is out or ignition is not operating | Step 3 |
| Gas odor or carbon-monoxide alarm | Possible gas leak or unsafe combustion | Leave and contact the gas utility or emergency services |
| Hot water lasts a few minutes, then turns cold | High demand, failed element, or recovery problem | Steps 4 and 6 |
| Breaker trips whenever the heater starts | Damaged wiring, element, or control | Step 1; leave breaker off |
| Reset control works briefly, then trips again | High-limit condition was not corrected | Step 5 |
| One faucet is cold while others are hot | Aerator, fixture valve, line, or mixing valve | Step 7 |
| Tankless unit shows a flow warning | Low flow, restricted inlet, or scale | Step 8 |
| Water is leaking from the heater area | Tank, connection, or pressure-control leak | Shut off power and water; call a professional |
Mistakes that make it worse
- Bypassing the high-limit control. This removes an overheating safeguard and can damage the tank or create a safety hazard.
- Resetting a breaker that trips again. Repeated switching does not repair a short circuit, damaged element, or wiring fault.
- Testing for gas with a flame. Use the utility’s instructions instead, and leave immediately if you smell gas.
- Opening the tank or element panel. A pressurized tank and live electrical connections are not appropriate areas for owner repair.
- Adjusting the thermostat repeatedly. A higher setting can increase scald risk while leaving a failed heating component unchanged.
- Ignoring leaks or burner instability. A leak, unusual flame, soot, or repeated shutdown should be checked by a qualified professional.
When to call a professional
- Any gas work: Call a licensed gas professional for gas lines, gas valves, burners, pilot systems that will not remain lit, or a suspected gas leak. Leave the building if you smell gas.
- Internal electrical work: Call an electrician or qualified water-heater technician when the breaker trips repeatedly, wiring is damaged, the plug is hot, or the control must be opened.
- Leaking water: A leaking tank, supply connection, drain valve, or relief pipe requires prompt service. Do not open the tank or attempt to repair a pressurized connection.
- Heating-component replacement: A failed thermostat, heating element, control module, or safety switch should be tested and replaced with power disconnected.
- Internal faults: Persistent tankless error codes, repeated flame-sensor faults, blocked venting, or scale-related shutdowns need professional diagnosis.
- Tank replacement or installation: Have a qualified professional remove, disconnect, install, and pressure-test a replacement heater.
How to keep it from happening again
- Follow the manufacturer’s schedule for sediment flushing and tankless descaling rather than using an improvised cleaning method.
- Inspect visible water connections and the area under the heater for moisture, corrosion, or discoloration.
- Keep the gas vent and any air-intake opening clear from debris, without servicing the vent yourself.
- Check the temperature and relief-valve area according to the manual, and keep the relief discharge path unobstructed.
- Avoid setting the water temperature excessively high, especially where children or older adults use the hot water.
- Insulate accessible hot-water piping when it helps reduce standby heat loss, and service the heater before a long period of nonuse if the manual recommends it.
Frequently asked questions
Why is my water heater not heating after a power outage?
The breaker may have tripped, or a gas heater may need its pilot or ignition cycle restored. Check the power and fuel status without opening the unit. If the breaker trips again or you smell gas, leave the breaker off and call the appropriate professional. A: The breaker may have tripped, or a gas heater may need its pilot or ignition cycle restored. Check the power and fuel status without opening the unit. If the breaker trips again or you smell gas, leave the breaker off and call the appropriate professional.
How long should a water heater take to heat?
Recovery time depends on the heater type, capacity, starting temperature, and condition. Use the manufacturer’s stated recovery time rather than a universal estimate. A unit that never produces hot water or repeatedly trips is not simply recovering normally.
Is it safe to reset a water heater?
Only use an accessible reset control exactly as the manual directs, with the power switched off during the reset. Never bypass or jumper a safety switch. If the breaker trips again or the reset does not restore heating, call a technician.
Why does my gas water heater pilot light keep going out?
Possible causes include an interrupted pilot, a dirty flame-sensing component, or a combustion or venting problem. Do not dismantle the control, bypass the sensor, or repeatedly relight the unit. A licensed gas professional should diagnose it.
Why do I have hot water at one faucet but not another?
The issue may be a clogged aerator, a closed fixture valve, a blocked supply line, or a thermostatic mixing valve. Clean the aerator only after closing the local hot-water valve. If the problem continues, have a plumber inspect the concealed parts.
Does a tankless water heater need maintenance?
Yes, the manufacturer may specify flushing, descaling, filter checks, or other service. Follow the model-specific instructions and stop if the procedure involves opening gas, electrical, or water connections. A qualified technician can handle component-level cleaning safely.
What this guide is based on
- U.S. Department of Energy energy.gov
- Rheem rheem.com
- A. O. Smith aosmith.com
Revision history
- Updated and re-checked against sources.
- First published.
Did this fix it?
Thanks. Glad it's sorted.
Sorry it's still not right. Recheck the symptom checker above, or tell us what you're seeing.