On this page

Quick answer

A dryer that tumbles but stays cold is often stopped by lint buildup, a blocked vent, the wrong heat setting, or a power or gas-supply issue. Start by selecting a heat cycle, cleaning the lint screen, checking the vent, and confirming power. Gas ignition faults and failed electric heating parts need professional service.

At a glance

Time
15–60 min
Difficulty
Moderate
You'll need
Flashlight, lint brush, vacuum hose, stable stool, appliance manual
Cost
Free for most checks; service or parts may cost more
Works on
Gas and electric dryers, including newly installed units
Not covered
Gas valves, burner repairs, or internal electrical work

Why does a dryer stop heating?

Gas and electric dryers create heat in different ways, but both need moving air. A gas dryer sends air across a burner, while an electric dryer heats air with an element and a blower. If airflow is restricted, a thermal cutoff may stop heating to protect the dryer. A packed lint screen or crushed vent can therefore produce a no-heat symptom.

Electrical parts can also stop producing heat. Depending on the model, the problem may involve a heating element, thermal fuse, thermal cutoff, blower motor, or control system. A gas dryer may fail to ignite, ignite without staying lit, or have a fuel-supply or ignition problem. Those faults are different from selecting Air Fluff or another no-heat cycle, where the drum tumbles by design.

Start with the controls, airflow, power, and installation because these are easy to check and often explain the symptom. If those checks do not restore heat, a qualified technician can test the components that are not safe or practical for you to access.

Before you start

Let the dryer finish its cycle and cool before reaching near the drum, lint screen, or exhaust duct. Before any hands-on inspection, unplug an electric dryer or switch off its breaker. For a gas dryer, turn off the controls and let it cool; do not remove a burner cover, gas fitting, or valve.

Gas warning: If you smell gas, leave the building without operating switches, starting the dryer, or using a phone inside. Call the gas utility’s emergency line from a safe location, or call emergency services. Do not light a match or test for a leak with a flame.

Have a flashlight, lint screen brush, vacuum with a hose attachment, stable stool, and the model manual ready. Electric dryers normally use a dedicated 240-volt circuit in the US. Do not use an extension cord or adapter. Any gas connection, new electrical circuit, or receptacle work should be handled by a qualified installer.

Step 1 Run a heat cycle and confirm heating is selected

This fix works because a dryer may tumble normally while a no-heat setting keeps the heater off. It also rules out a temporary delay before the heating portion of the cycle begins.

  1. Choose a normal heat option, such as Medium or High, rather than Air Fluff, Refresh, or another no-heat setting. Use the names shown on your model.
  2. Use a normal load of dry clothing and close the door. An empty drum may not trigger every moisture-sensing heat request.
  3. Start the cycle and allow the drum to tumble. Do not repeatedly stop and restart it while waiting.
  4. Once the heating portion begins, check for warm air at the exhaust vent. If there is no warmth after several minutes of active heating, continue with the next steps.
  5. Cancel the cycle if you notice a burning odor, smoke, or unusual noise. Switch off the breaker and unplug an electric dryer.

For a new dryer

A new dryer may perform sensor or calibration activity before heating. Follow any panel instructions and let that sequence finish. If the display identifies a specific setup or calibration step, follow the model manual rather than repeatedly starting the cycle.

You have fixed this step if the heating portion produces warm air and the load becomes warm instead of remaining cold.

Step 2 Clean the lint screen and accessible lint path

This fix works because restricted airflow can trigger a heating cutoff or prevent the burner and blower from warming the drum properly. Lint often collects at the screen, in the opening around it, and farther inside the cabinet.

  1. Stop the dryer. Unplug an electric dryer or switch off its breaker before reaching near the lint screen. For a gas dryer, switch it off and allow the drum to cool.
  2. Pull the lint screen out using the handle or tabs described in the manual. Do not remove screws or separate housing pieces.
  3. Brush lint off the screen with a dryer-safe lint brush. Hold the vacuum hose outside the opening so you cannot pull loose debris into the drum.
  4. Look into the exposed screen opening and clean visible lint around its edges. Keep your fingers and tools away from any internal fan, wiring, or burner components.
  5. If the screen is torn, distorted, or no longer fits securely, replace it with the correct model-matched part according to the manual.
  6. Slide the screen back until it seats fully. Start a normal heat cycle and check for stronger airflow at the vent.

You have fixed this step if the screen is clean and seated, air moves freely through the opening, and the dryer heats during the next cycle. If lint is packed deeper inside the cabinet, a technician must clean that area safely.

Step 3 Check the power supply and gas service

This fix works because the drum, controls, and heater need their required energy sources. A tripped breaker, disconnected plug, or suspended gas service can stop the entire heat cycle even when the display still works.

For an electric dryer

  1. Check the breaker and switch it off before touching the plug or receptacle. Unplug the dryer before inspecting it.
  2. Look for scorch marks, melting, a loose fit, or a burnt odor on the plug and outlet. Do not reconnect damaged parts; have an electrician inspect them.
  3. Reconnect the dryer directly to its dedicated outlet, then restore the breaker. Do not use an extension cord or adapter.
  4. If the breaker trips again, leave it off and call an electrician or an appliance technician. Do not keep resetting it.

For a gas dryer

  1. Do not begin if you smell gas. Follow the gas warning in “Before you start” and leave the area.
  2. Check whether your gas utility has posted a service suspension. If other gas appliances in the home are also not working, contact the utility.
  3. Do not operate the appliance’s gas valve, loosen a fitting, or test the supply with a flame. Those checks require a licensed gas appliance technician.
  4. Restore power to the dryer controls and check for normal control-panel response before repeating the heat cycle.

You have fixed this step if power remains on without another trip and gas service is confirmed as active. If both are available but the dryer remains cold, the heat circuit itself may need service.

Step 4 Check the exhaust vent for moving air

This fix works because the dryer must move heated air out through the exhaust duct. A disconnected, crushed, or lint-filled duct reduces airflow, which can stop heating or activate a protective cutoff.

  1. Run a heat cycle and watch the exterior vent from a safe position. Strong moving air should be noticeable during the cycle.
  2. Stop the cycle and let the dryer cool. Unplug an electric dryer or switch off its breaker before disconnecting the exhaust connection.
  3. Disconnect the duct at the dryer and wall connection without removing screws, brackets, or cabinet panels.
  4. Inspect the accessible duct for lint, crushed sections, bends, gaps, or disconnected joints. Pull the duct straight away from the wall without stretching it.
  5. Replace a crushed or improvised duct with an approved duct suitable for the installation. Follow the dryer manual and local requirements for duct material and routing.
  6. Reconnect the duct tightly at both ends. Clear debris from the exterior opening and make sure its cover can open freely.

For front-load and top-load dryers

Both types normally discharge air through a rear duct. If lint lies beyond the lint-screen opening, do not pull an internal duct through the cabinet. Have the technician remove and clean it without damaging the blower or heater.

You have fixed this step if warm air leaves the exterior vent, air is drawn into the dryer opening, and the heating portion begins working normally.

Step 5 Check that the drum and blower are moving

This fix works because a stopped drum, failed belt, or failed blower can prevent heat from reaching the load. In some dryers, the blower has its own motor; in others, a belt drives it from the drum motor.

  1. Stop and cool the dryer. Unplug an electric dryer or switch off its breaker before touching the drum or opening any accessible mechanical cover.
  2. Open the door and turn the drum gently by hand. It should move without grinding, catching, or requiring force.
  3. Close the door and run a brief heat cycle while watching the drum. Note whether it rotates smoothly and whether air moves at the exterior vent.
  4. If the drum turns but no air leaves the vent, the blower or its drive may have failed. If the drum stops, the belt, idler, or motor may have failed.
  5. Do not remove cabinet panels to reach a belt, pulley, motor, or blower. Record what moved and what did not, then arrange professional service.

You have fixed this step if the drum rotates evenly and the blower moves air through the duct. Only then can a missing heat cycle be judged separately from an airflow or drive problem.

Step 6 Verify the installation on a new or moved dryer

This fix works because an unremoved shipping restraint, leftover packing material, incomplete installation, or unfinished calibration cycle can keep a new dryer from heating. Installation errors are more likely than a failed new heat component.

  1. Find the model manual and confirm that all shipping bolts or restraints have been removed. If the drum cannot turn freely, contact the installer; do not cut or pry the hardware.
  2. Unplug an electric dryer or switch off its breaker before checking the drum. For a gas dryer, switch it off and let it cool. Remove only loose packing material that you can reach safely.
  3. Check that the dryer is level, the door closes and latches, and the lint screen fits completely in its opening.
  4. Confirm that the exhaust duct is connected without a crushed section and that the exterior opening is clear.
  5. For an electric dryer, confirm that the installer connected it to the proper dedicated outlet. For a gas dryer, have the licensed installer confirm the gas connection and vent setup.
  6. Run the first normal heat cycle as directed by the manual. Let any sensor, calibration, or diagnostic sequence finish before judging the dryer.
  7. If the cycle completes without warmth, contact the original installer or an authorized service technician.

You have fixed this step if the installation checklist is complete and the first normal heat cycle warms the drum and load. Do not attempt to alter gas or electrical connections yourself.

Step 7 Have the electric heat circuit checked

This fix works because a failed heating element, thermal fuse, cutoff, blower motor, or control component can leave the dryer running without heat. Testing and replacing those parts requires access to protected electrical areas.

  1. Unplug the dryer or switch off its breaker before service begins, and keep the power off until the appliance is properly reassembled.
  2. Record the symptoms: whether the controls respond, whether the drum turns, whether air leaves the vent, and whether the breaker trips.
  3. Ask a qualified appliance technician to check the heating element, thermal protection devices, blower motor, and relevant controls.
  4. Do not remove the rear panel, probe internal terminals, replace a thermal device, or bypass a safety cutoff.
  5. After the repair, run a normal heat cycle and confirm that both airflow and warming return.

If the breaker trips again

Stop using the dryer and have an electrician inspect the circuit and receptacle. Repeated breaker trips, a burnt electrical smell, melting, or a scorched outlet should not be tested again.

You have fixed this step if a qualified repair restores heat without the breaker tripping and without bypassing a safety device.

Step 8 Have gas ignition or burner service completed

This fix works because a gas dryer needs a successful ignition and a burner that stays lit. The igniter, flame-sensing device, gas valve, and burner are gas-system parts that should be serviced by a licensed professional.

  1. Confirm there is no gas odor. If there is, do not start or operate the dryer; leave and follow the gas warning in “Before you start.”
  2. Start a heat cycle from a safe standing position and keep clear of the door and burner area. Do not remove a panel or reach into the burner opening.
  3. If you hear repeated clicking without heat, or the dryer starts but does not remain warm, cancel the cycle and record the sequence.
  4. Check whether gas service has been suspended through a utility notice or other gas appliances. If service is active, the fault may still be in the ignition system.
  5. Call a licensed gas appliance technician to inspect the igniter, flame-sensing device, burner, and supply. Only the technician should work on the gas valve, gas fittings, or burner parts.
  6. Do not keep restarting the dryer to force ignition. Repeated unsuccessful attempts do not repair the system.

If the dryer heats briefly and then cools

An intermittent gas dryer may have a burner that is not staying lit or a control problem. Describe the exact sequence to the technician. Do not adjust the burner or gas valve yourself.

You have fixed this step if the technician confirms safe ignition and a normal heat cycle produces warm air without repeated shutdowns.

Symptom checker

What you notice Likely cause Fix (step number)
The drum tumbles, but the air stays cold Lint restriction, blocked vent, or a no-heat setting Steps 1, 2, and 4
The dryer starts but never becomes warm Heat setting, power supply, or failed heat component Steps 1, 3, 7, and 8
The breaker trips during the cycle Electrical fault or overload Step 3
No air leaves the exterior vent Disconnected, crushed, or clogged duct Step 4
The drum turns, but no air moves Blower, belt, idler, or motor failure Step 5
The gas dryer clicks without heating Ignition or flame-sensing failure Step 8
The gas dryer heats briefly, then cools Burner not staying lit or control fault Step 8
A new dryer does not heat after installation Shipping restraint, setup, or calibration issue Step 6
Airflow is weak and the load stays damp Restricted lint path or exhaust duct Steps 2 and 4

Mistakes that make it worse

  • Do not treat a repeated no-heat cycle as a normal way to dry clothes; it can hide a developing airflow or heat-system fault.
  • Do not leave the lint screen loose, damaged, or partly inserted after cleaning it.
  • Do not reconnect a scorched, loose, or discolored plug, or keep resetting a breaker that trips again.
  • Do not use a crushed duct, an improvised connector, or an indoor vent hood when the manufacturer requires an exterior exhaust.
  • Do not remove burner parts, operate the gas valve, open electrical panels, or bypass a thermal cutoff.
  • Do not keep restarting a gas dryer that repeatedly clicks, stops heating, or leaves a gas odor.

When to call a professional

  • Call the gas utility or emergency services if you smell gas, hear hissing near the dryer, or cannot safely leave the area.
  • Call a licensed gas appliance technician if the burner will not ignite, will not stay lit, or needs gas-valve, igniter, flame-sensor, fitting, or burner work.
  • Call an electrician if the breaker trips repeatedly, the outlet is damaged or discolored, or you notice a burnt electrical smell.
  • Call an appliance technician for internal wiring, control-board, heating-element, thermal-fuse, blower-motor, belt, or idler problems.
  • Call the installer if a new dryer still has shipping hardware, was connected to the wrong power source, has an incomplete gas installation, or remains cold after its setup cycle.
  • Call a vent professional if the duct is crushed inside the wall, disconnected in a difficult location, or cannot be reached safely from the dryer.

How to keep it from happening again

  • Clean the lint screen as often as the model manual recommends, and inspect the accessible screen opening during each cleaning.
  • Check the exterior exhaust opening and the accessible duct for lint, debris, crushing, and disconnection.
  • Keep the area around the dryer clear so the inlet can draw air and you can reach the screen safely.
  • Avoid overloading the drum or hanging items that block the door, gasket, or lint path.
  • Have gas and electrical connections inspected by qualified professionals whenever the dryer is installed, moved, or repaired.
  • Arrange service promptly if heating becomes intermittent or the breaker trips; do not wait for repeated failures.

Frequently asked questions

Why is my dryer not heating up?

A no-heat setting, restricted airflow, interrupted power, or a failed heating component can all stop the heat. Check the cycle selection, lint screen, exhaust vent, and power before arranging service.

Why does my dryer tumble but stay cold?

The drum can turn while the burner, heating element, or blower is not working. Cleaning the lint path and checking the vent may restore heat; otherwise, a technician should test the heat system.

How long should a dryer take to heat?

It depends on the model, cycle, load, and selected setting. Warm air should appear during the heating portion; if the drum remains cold after that portion begins, keep troubleshooting.

Can I use a dryer that does not heat?

If there is no gas odor, burning smell, or breaker trip, you can finish one load if practical, but repeated no-heat cycles are not a good workaround. Stop the dryer and unplug it or switch off its breaker if you notice a safety warning.

Do I need a technician for a gas dryer that will not heat?

You can safely check the settings, lint screen, vent, and whether gas service has been suspended. If the burner does not ignite or stay lit, call a licensed gas appliance technician; do not touch the gas valve or burner parts.

Why is my new dryer not heating?

Confirm that shipping restraints are removed, packing material is gone, and installation is complete. Let any calibration sequence finish, then contact the installer if a normal heat cycle still leaves the drum cold.

What this guide is based on

Revision history

  1. Updated and re-checked against sources.
  2. First published.

Did this fix it?

Mixtvnowcom.org editors Editorial team

The Mixtvnowcom.org editors write and check every guide on the site against the manufacturer instructions and official sources it lists, and keep each guide's revision history up to date.

More guides from the editors